Five Questions Regarding Moisture Control for your PFT or CPET Device
Pulmonary Function Testing (PFT) and Cardiopulmonary Exercise Testing (Metabolic Testing or CPET) have been available as a source of diagnosis and assessment of respiratory conditions for years.
COVID-19 put a strain on the ability of labs to be operational, and now, as testing has picked up, labs have adopted varying procedures for keeping patients safe. As you develop solutions to aid in the safe operation of PFT and CPET equipment, we would like to offer insights to support you. Below, you can review five things to consider as you refine your PFT device offering.
EXPLORING CHANGES IN MOISTURE CONTROL
How will added moisture control affect our test results?
Without sufficient moisture control, condensation in the sampling line becomes an issue, slowing readings and affecting results.
The same concept applies to Metabolic Testing. With every exhaled breath, water vapor is being pushed to the sampling line. Nafion™ Tubing removes the vapor, enabling proper measurement and reducing the opportunities for moisture to damage the critical device.
For the engineer, this could mean inefficiencies in measurements or costly damage to the device. For the clinicians, this could mean incorrect or slow measurements, downtime for device repair, and potentially retesting the patient. The effects are costly and delay patient results and diagnosis.
The reason respiratory engineers turn to Salaera is to mitigate risks of moisture issues with a customized Nafion™ Tubing solution. Nafion™ Tubing can be connected to your chosen sampling line, or we can support your team in designing and manufacturing a unique sampling line for your device.
The savings in cost and time to you, the technician using your device, and the patient in need of a diagnosis or assessment make Nafion™ Tubing a solid choice for moisture control.
What could affect drying performance in my Nafion™ Tubing?
Dehumidification performance can be diminished by a variety of factors. Given that PFT and CPET are performed under a variety of conditions, we can only share what we have learned.
Since Nafion™ Tubing is used with PFT and CPET testing equipment in environments where heavy breathing is needed, technicians may want to disinfect equipment in between patients. Our ME Dryers, made from Nafion™ Tubing, are intended for single-patient use. When our solutions come into contact with substances like NaCl or Alconox, drying efficiency decreases significantly. When Nafion™ Tubing was exposed to bleach and H2O2, the drying efficiency shrank to approximately 33% and 63%, respectively. The diminished dehumidification performance can be costly to labs and make the technician’s job harder, so supporting you in exploring ways to avoid reduced performance is important to us.